Some motherboards and expansion cards add some simple hardware, usually just a ROM, that allows the computer to boot from a RAID array. After booting, access to the RAID array is handled by software running on the computer's main processor. This “hardware-assisted software RAID” gives RAID arrays that are not dependent on any particular operating system, and which are functional even before an operating system is loaded.
Several levels of RAID are supported, depending on the hardware in use. See graid(8) for a complete list.
graid(8) requires the geom_raid.ko
kernel module, which is included in the
GENERIC
kernel starting with FreeBSD 9.1.
If needed, it can be loaded manually with
graid load
.
Software RAID devices often have a menu that can be entered by pressing special keys when the computer is booting. The menu can be used to create and delete RAID arrays. graid(8) can also create arrays directly from the command line.
graid label
is used to create a new
array. The motherboard used for this example has an Intel
software RAID chipset, so the Intel
metadata format is specified. The new array is given a label
of gm0
, it is a mirror
(RAID1), and uses drives
ada0
and
ada1
.
Some space on the drives will be overwritten when they are made into a new array. Back up existing data first!
#
graid label Intel gm0 RAID1 ada0 ada1
GEOM_RAID: Intel-a29ea104: Array Intel-a29ea104 created. GEOM_RAID: Intel-a29ea104: Disk ada0 state changed from NONE to ACTIVE. GEOM_RAID: Intel-a29ea104: Subdisk gm0:0-ada0 state changed from NONE to ACTIVE. GEOM_RAID: Intel-a29ea104: Disk ada1 state changed from NONE to ACTIVE. GEOM_RAID: Intel-a29ea104: Subdisk gm0:1-ada1 state changed from NONE to ACTIVE. GEOM_RAID: Intel-a29ea104: Array started. GEOM_RAID: Intel-a29ea104: Volume gm0 state changed from STARTING to OPTIMAL. Intel-a29ea104 created GEOM_RAID: Intel-a29ea104: Provider raid/r0 for volume gm0 created.
A status check shows the new mirror is ready for use:
#
graid status
Name Status Components raid/r0 OPTIMAL ada0 (ACTIVE (ACTIVE)) ada1 (ACTIVE (ACTIVE))
The array device appears in
/dev/raid/
. The first array is called
r0
. Additional arrays, if present, will
be r1
, r2
, and so
on.
The BIOS menu on some of these devices
can create arrays with special characters in their names. To
avoid problems with those special characters, arrays are given
simple numbered names like r0
. To show
the actual labels, like gm0
in the
example above, use sysctl(8):
#
sysctl kern.geom.raid.name_format=1
Some software RAID devices support more than one volume on an array. Volumes work like partitions, allowing space on the physical drives to be split and used in different ways. For example, Intel software RAID devices support two volumes. This example creates a 40 G mirror for safely storing the operating system, followed by a 20 G RAID0 (stripe) volume for fast temporary storage:
#
graid label -S 40G Intel gm0 RAID1 ada0 ada1
#
graid add -S 20G gm0 RAID0
Volumes appear as additional
r
entries
in X
/dev/raid/
. An array with two volumes
will show r0
and
r1
.
See graid(8) for the number of volumes supported by different software RAID devices.
Under certain specific conditions, it is possible to convert an existing single drive to a graid(8) array without reformatting. To avoid data loss during the conversion, the existing drive must meet these minimum requirements:
The drive must be partitioned with the MBR partitioning scheme. GPT or other partitioning schemes with metadata at the end of the drive will be overwritten and corrupted by the graid(8) metadata.
There must be enough unpartitioned and unused space at the end of the drive to hold the graid(8) metadata. This metadata varies in size, but the largest occupies 64 M, so at least that much free space is recommended.
If the drive meets these requirements, start by making a full backup. Then create a single-drive mirror with that drive:
#
graid label Intel gm0 RAID1 ada0 NONE
graid(8) metadata was written to the end of the drive in the unused space. A second drive can now be inserted into the mirror:
#
graid insert raid/r0 ada1
Data from the original drive will immediately begin to be copied to the second drive. The mirror will operate in degraded status until the copy is complete.
Drives can be inserted into an array as replacements for drives that have failed or are missing. If there are no failed or missing drives, the new drive becomes a spare. For example, inserting a new drive into a working two-drive mirror results in a two-drive mirror with one spare drive, not a three-drive mirror.
In the example mirror array, data immediately begins to be copied to the newly-inserted drive. Any existing information on the new drive will be overwritten.
#
graid insert raid/r0 ada1
GEOM_RAID: Intel-a29ea104: Disk ada1 state changed from NONE to ACTIVE. GEOM_RAID: Intel-a29ea104: Subdisk gm0:1-ada1 state changed from NONE to NEW. GEOM_RAID: Intel-a29ea104: Subdisk gm0:1-ada1 state changed from NEW to REBUILD. GEOM_RAID: Intel-a29ea104: Subdisk gm0:1-ada1 rebuild start at 0.
Individual drives can be permanently removed from a from an array and their metadata erased:
#
graid remove raid/r0 ada1
GEOM_RAID: Intel-a29ea104: Disk ada1 state changed from ACTIVE to OFFLINE. GEOM_RAID: Intel-a29ea104: Subdisk gm0:1-[unknown] state changed from ACTIVE to NONE. GEOM_RAID: Intel-a29ea104: Volume gm0 state changed from OPTIMAL to DEGRADED.
An array can be stopped without removing metadata from the drives. The array will be restarted when the system is booted.
#
graid stop raid/r0
Array status can be checked at any time. After a drive was added to the mirror in the example above, data is being copied from the original drive to the new drive:
#
graid status
Name Status Components raid/r0 DEGRADED ada0 (ACTIVE (ACTIVE)) ada1 (ACTIVE (REBUILD 28%))
Some types of arrays, like RAID0
or
CONCAT
, may not be shown in the status
report if disks have failed. To see these partially-failed
arrays, add -ga
:
#
graid status -ga
Name Status Components Intel-e2d07d9a BROKEN ada6 (ACTIVE (ACTIVE))
Arrays are destroyed by deleting all of the volumes from them. When the last volume present is deleted, the array is stopped and metadata is removed from the drives:
#
graid delete raid/r0
Drives may unexpectedly contain graid(8) metadata, either from previous use or manufacturer testing. graid(8) will detect these drives and create an array, interfering with access to the individual drive. To remove the unwanted metadata:
Boot the system. At the boot menu, select
2
for the loader prompt. Enter:
OKset kern.geom.raid.enable=0
OKboot
The system will boot with graid(8) disabled.
Back up all data on the affected drive.
As a workaround, graid(8) array detection can be disabled by adding
kern.geom.raid.enable=0
to /boot/loader.conf
.
To permanently remove the graid(8) metadata
from the affected drive, boot a FreeBSD installation
CD-ROM or memory stick, and select
Shell
. Use status
to find the name of the array, typically
raid/r0
:
#
graid status
Name Status Components raid/r0 OPTIMAL ada0 (ACTIVE (ACTIVE)) ada1 (ACTIVE (ACTIVE))
Delete the volume by name:
#
graid delete raid/r0
If there is more than one volume shown, repeat the process for each volume. After the last array has been deleted, the volume will be destroyed.
Reboot and verify data, restoring from backup if
necessary. After the metadata has been removed, the
kern.geom.raid.enable=0
entry in
/boot/loader.conf
can also be
removed.