Stop-Cluster
Node
Syntax
Stop-ClusterNode
[[-Name] <StringCollection>]
[-Wait <Int32>]
[-InputObject <PSObject>]
[-Cluster <String>]
[-WhatIf]
[-Confirm]
[<CommonParameters>]
Description
The Stop-ClusterNode cmdlet stops the Cluster service on a node in a failover cluster. If stopping the node brings the cluster below quorum, the operation is not permitted. To stop the cluster, use the Stop-Cluster cmdlet instead.
Note: This cmdlet cannot be run remotely without Credential Security Service Provider (CredSSP) authentication on the server computer.
Examples
Example 1: Stop Cluster service on a local cluster node
PS C:\> Stop-ClusterNode -Name "node3"
Name State
---- -----
node3 Down
This example stops the Cluster service on the node named node3 of the local cluster.
Example 2: Stop Cluster service on a cluster node
PS C:\> Stop-ClusterNode -Name "node1" -Cluster "cluster2"
Name State
---- -----
node1 Down
This example stops the Cluster service on the node named node1 on the cluster named cluster2.
Optional Parameters
Specifies the name of the cluster on which to run this cmdlet.
If the input for this parameter is
.
or it is omitted, then the cmdlet runs on the local cluster.
Type: | String |
Position: | Named |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Prompts you for confirmation before running the cmdlet.
Type: | SwitchParameter |
Aliases: | cf |
Position: | Named |
Default value: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Specifies the cluster node to stop.
Type: | PSObject |
Position: | Named |
Default value: | None |
Accept pipeline input: | True (ByValue) |
Accept wildcard characters: | False |
Specifies the name of the cluster node to stop.
Type: | StringCollection |
Position: | 0 |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Specifies the time in seconds to wait for the cmdlet.
If the
Wait
parameter is not specified, then the cmdlet waits for completion.
If
-Wait 0
is specified, then the call is initiated and the cmdlet returns without waiting.
Type: | Int32 |
Position: | Named |
Default value: | None |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Shows what would happen if the cmdlet runs. The cmdlet is not run.
Type: | SwitchParameter |
Aliases: | wi |
Position: | Named |
Default value: | False |
Accept pipeline input: | False |
Accept wildcard characters: | False |
Inputs
Microsoft.FailoverClusters.PowerShell.ClusterNode