New in version 2.1.
Configures a front panel, sub-interface, SVI, management or loopback port on a Cumulus Linux switch. For bridge ports use the cl_bridge module. For bond ports use the cl_bond module. When configuring bridge related features like the “vid” option, please follow the guidelines for configuring “vlan aware” bridging. For more details review the Layer2 Interface Guide at http://docs.cumulusnetworks.com
- Alternate Debian network interface manager - ifupdown2 @ github.com/CumulusNetworks/ifupdown2
parameter | required | default | choices | comments |
---|---|---|---|---|
addr_method |
no | can be loopback for loopback interfaces or dhcp for dhcp interfaces. | ||
alias_name |
no | add a port description | ||
clagd_enable |
no | Enables the clagd daemon. This command should only be applied to the clag peerlink interface | ||
clagd_peer_ip |
no | IP address of the directly connected peer switch interface | ||
clagd_priority |
no | Integer that changes the role the switch has in the clag domain. The lower priority switch will assume the primary role. The number can be between 0 and 65535 | ||
clagd_sys_mac |
no | Clagd system mac address. Recommended to use the range starting with 44:38:39:ff. Needs to be the same between 2 Clag switches | ||
ipv4 |
no | list of IPv4 addresses to configure on the interface. use X.X.X.X/YY syntax. | ||
ipv6 |
no | list of IPv6 addresses to configure on the interface. use X:X:X::X/YYY syntax | ||
location |
no | [u'/etc/network/interfaces.d'] | interface directory location | |
mstpctl_bpduguard |
no | Enables BPDU Guard on a port in vlan-aware mode | ||
mstpctl_portadminedge |
no | Enables admin edge port | ||
mstpctl_portnetwork |
no | Enables bridge assurance in vlan-aware mode | ||
mtu |
no | set MTU. Configure Jumbo Frame by setting MTU to 9000. | ||
name |
yes | name of the interface | ||
pvid |
no | in vlan aware mode, defines vlan that is the untagged vlan | ||
speed |
no | set speed of the swp(front panel) or management(eth0) interface. speed is in MB | ||
vids |
no | in vlan aware mode, lists vlans defined under the interface | ||
virtual_ip |
no | define IPv4 virtual IP used by the Cumulus VRR feature | ||
virtual_mac |
no | define Ethernet mac associated with Cumulus VRR feature |
# Options ['virtual_mac', 'virtual_ip'] are required together # configure a front panel port with an IP cl_interface: name=swp1 ipv4=10.1.1.1/24 notify: reload networking # configure front panel to use DHCP cl_interface: name=swp2 addr_family=dhcp notify: reload networking # configure a SVI for vlan 100 interface with an IP cl_interface: name=bridge.100 ipv4=10.1.1.1/24 notify: reload networking # configure subinterface with an IP cl_interface: name=bond0.100 alias_name='my bond' ipv4=10.1.1.1/24 notify: reload networking # define cl_interfaces once in tasks # then write intefaces in variables file # with just the options you want. cl_interface: name: "{{ item.key }}" ipv4: "{{ item.value.ipv4|default(omit) }}" ipv6: "{{ item.value.ipv6|default(omit) }}" alias_name: "{{ item.value.alias_name|default(omit) }}" addr_method: "{{ item.value.addr_method|default(omit) }}" speed: "{{ item.value.link_speed|default(omit) }}" mtu: "{{ item.value.mtu|default(omit) }}" clagd_enable: "{{ item.value.clagd_enable|default(omit) }}" clagd_peer_ip: "{{ item.value.clagd_peer_ip|default(omit) }}" clagd_sys_mac: "{{ item.value.clagd_sys_mac|default(omit) }}" clagd_priority: "{{ item.value.clagd_priority|default(omit) }}" vids: "{{ item.value.vids|default(omit) }}" virtual_ip: "{{ item.value.virtual_ip|default(omit) }}" virtual_mac: "{{ item.value.virtual_mac|default(omit) }}" mstpctl_portnetwork: "{{ item.value.mstpctl_portnetwork|default('no') }}" mstpctl_portadminedge: "{{ item.value.mstpctl_portadminedge|default('no') }}" mstpctl_bpduguard: "{{ item.value.mstpctl_bpduguard|default('no') }}" with_dict: cl_interfaces notify: reload networking # In vars file # ============ cl_interfaces: swp1: alias_name: 'uplink to isp' ipv4: '10.1.1.1/24' swp2: alias_name: 'l2 trunk connection' vids: [1, 50] swp3: speed: 1000 alias_name: 'connects to 1G link' ########## # br0 interface is configured by cl_bridge ########## br0.100: alias_name: 'SVI for vlan 100' ipv4: '10.2.2.2/24' ipv6: '10:2:2::2/127' virtual_ip: '10.2.2.254' virtual_mac: '00:00:5E:00:10:10'
Common return values are documented here Common Return Values, the following are the fields unique to this module:
name | description | returned | type | sample |
---|---|---|---|---|
msg | human-readable report of success or failure | always | string | interface bond0 config updated |
changed | whether the interface was changed | changed | bool | True |
Note
because the module writes the interface directory location. Ensure that /etc/network/interfaces
has a ‘source /etc/network/interfaces.d/*’ or whatever path is mentioned in the location
attribute.
Note
For the config to be activated, i.e installed in the kernel, “service networking reload” needs be be executed. See EXAMPLES section.
For more information on what this means please read Core Modules
For help in developing on modules, should you be so inclined, please read Community Information & Contributing, Helping Testing PRs and Developing Modules.